Publisher: Raipur Asian Pharma Press 2023Edition: Vo.13(1), Jan-Mar.Description: 7-12p.Subject(s): PHARMACEUTICSOnline resources: Click here In: Asian journal of pharmaceutical analysisSummary: A new accurate, specific, precise, high performance liquid chromatographic (HPLC) method has been developed and validated for the determination of Febuxostat in bulk and in its pharmaceutical dosage forms of tablet. Acetonitrile: Methanol (70:30) was used as the mobile phase at a flow rate of 1.0ml/min using a Symmetry C18 column Finepack SIL C18T-5 (250x4.6mm, 5m). The effluent was spectroscopically monitored at 314nm. The intraday and inter-day precisions showed coefficients of variation ranged from 0.62% to 2.78% at different levels of concentrations. The calibration curve was linear with a correlation coefficient of 0.9947. The averages of the absolute and relative recoveries were found to be 98.67% to 98.96%. The proposed HPLC method was successfully applied to quantify the amount of Febuxostat in bulk and dosage forms in quality control.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2023-1673
Total holds: 0

A new accurate, specific, precise, high performance liquid chromatographic (HPLC) method has been developed and validated for the determination of Febuxostat in bulk and in its pharmaceutical dosage forms of tablet. Acetonitrile: Methanol (70:30) was used as the mobile phase at a flow rate of 1.0ml/min using a Symmetry C18 column Finepack SIL C18T-5 (250x4.6mm, 5m). The effluent was spectroscopically monitored at 314nm. The intraday and inter-day precisions showed coefficients of variation ranged from 0.62% to 2.78% at different levels of concentrations. The calibration curve was linear with a correlation coefficient of 0.9947. The averages of the absolute and relative recoveries were found to be 98.67% to 98.96%. The proposed HPLC method was successfully applied to quantify the amount of Febuxostat in bulk and dosage forms in quality control.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha